Levy O M, Gittelman M C, Strashun A M, Cohen E L, Fine E J
J Urol. 1983 May;129(5):975-7. doi: 10.1016/s0022-5347(17)52495-7.
We analyzed retrospectively 99mtechnetium scrotal scan findings in 37 patients with acute scrotal pain. Correlation between scan interpretation, and either surgical findings and/or final clinical diagnosis revealed an accuracy of 89 per cent. Only 1 false negative and 3 false positive results were recorded. Scan data revealed a positive predictive value of 75 per cent, negative predictive value of 96 per cent, sensitivity of 90 per cent and specificity of 89 per cent. An inter-institutional observer study also was conducted to assess reliability of the scan, resulting in an 88 per cent agreement. The testicular scan has been found to be an accurate and reliable method to distinguish between epididymo-orchitis and testicular torsion.
我们回顾性分析了37例急性阴囊疼痛患者的锝-99m阴囊扫描结果。扫描结果解读与手术发现和/或最终临床诊断之间的相关性显示准确率为89%。仅记录到1例假阴性和3例假阳性结果。扫描数据显示阳性预测值为75%,阴性预测值为96%,敏感性为90%,特异性为89%。还进行了一项机构间观察者研究以评估扫描的可靠性,结果一致性为88%。睾丸扫描已被证明是区分附睾炎和睾丸扭转的准确且可靠的方法。