Suppr超能文献

[通过中子活化分析测定羟基磷灰石钙中的钙/磷原子比]

[Determination of Ca/P atomic ratio in calcium-hydroxyapatite by neutron activation analysis].

作者信息

Mizumoto Y, Iwata S

出版信息

Radioisotopes. 1983 Jan;32(1):22-5.

PMID:6856880
Abstract

The Ca/P atomic ratios of synthesized calcium-hydroxyapatite (Ca10(PO4)6(OH2) were determined by neutron activation analysis. In order to obtain calibration curves, the standard samples, such as calcium monohydrogenphosphate, calcium dihydrogenphosphate, etc., were prepared. gamma and beta ray spectra, and beta ray intensities of calcium-hydroxyapatite and standard samples irradiated with reactor neutrons were measured by using a Ge(Li) detector, a low background beta ray spectrometer and GM detector. Based on these results, deviation coefficient of the calibration curve, accuracy of the Ca/P atomic ratio, minimum determination limit, etc. were compared in detail. From the present analysis, the Ca/P atomic ratio of calcium-hydroxyapatite was able to obtain with the standard deviation of about 2% for 1 mg sample.

摘要

通过中子活化分析测定合成的羟基磷灰石(Ca10(PO4)6(OH)2)的钙磷原子比。为了获得校准曲线,制备了磷酸氢钙、磷酸二氢钙等标准样品。使用锗锂探测器、低本底β射线光谱仪和盖革-弥勒探测器测量了用反应堆中子辐照的羟基磷灰石和标准样品的γ射线和β射线光谱以及β射线强度。基于这些结果,详细比较了校准曲线的偏差系数、钙磷原子比的准确度、最小测定限等。根据目前的分析,对于1毫克样品,羟基磷灰石的钙磷原子比的标准偏差约为2%。