Suppr超能文献

血液灌流期间的凝血障碍(作者译)

[Disorders of blood coagulatiion during haemoperfusion (author's transl)].

作者信息

Niessner H, Pichler M

出版信息

Wien Klin Wochenschr. 1977 May 13;89(10):347-50.

PMID:68628
Abstract

Charcoal haemoperfusion of patient may cause a fall in thrombocyte and fibrinogen levels. The possible cause of these changes in haemostasis was investigated by means of five haemoperfusion devices which were filled with 2000 ml ACD fresh blood and perfused for three hours. A continous reduction in the thrombocytes and the plasma coagulation proteins resulted, while the ethanol test and the level of fibrin degradation products stayed within normal levels. These results indicate the adsorption of thrombocytes and protein on to the surface of the charcoal haemoperfusion device. An activation of the coagulation system (i. e. disseminated intravasal coagulation, fibrinolysis) appears unlikely.

摘要

患者进行炭血液灌注可能会导致血小板和纤维蛋白原水平下降。通过五个装有2000毫升ACD新鲜血液并灌注三小时的血液灌注装置,对这些止血变化的可能原因进行了研究。结果导致血小板和血浆凝血蛋白持续减少,而乙醇试验和纤维蛋白降解产物水平保持在正常范围内。这些结果表明血小板和蛋白质吸附在了炭血液灌注装置表面。凝血系统的激活(即弥散性血管内凝血、纤维蛋白溶解)似乎不太可能。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验