Sugiura K, Steiner M, Baldini M G
J Lab Clin Med. 1980 Oct;96(4):640-53.
Platelet-associated immunoiglobulin weas measured by the use of fluorescent anti-IgG antibody. The method is simple, rapid, and sensitive and provides a precise quantitative assay of bound (direct) and free (indirect) IgG with platelet specificity. We have evaluated this test in 30 normal volunteers and in 50 patients with immune and nonimmune, treated and untreated thrombocytopenias. All patients with immune thrombocytopenias (acute and chronic idiopathic thrombocytopenic purpura and systemic lupus etythematosus) having platelet counts < 100,000/microliter had elevated levels of platelet-bound IgG, and 86% had also positive results in the indirect assay. All patients with nonimmunological thrombocytopenias showed normal results in the direct and indirect assay of platelet-associated immunoglobulin. In patients studied repeatedly during the course of their illness, an inverse relation was found between platelet count and level of platelet-bound IgG. Patients with systemic lupus erythematosus presented clear exceptions to this rule. Investigations of the absorbability of platelet autoantibodies and alloantibodies showed that this assay can readily differentiate between these two antibody species and can also identify specificities of alloantibodies.
采用荧光抗IgG抗体检测血小板相关免疫球蛋白。该方法简便、快速且灵敏,能对具有血小板特异性的结合(直接)和游离(间接)IgG进行精确的定量测定。我们在30名正常志愿者以及50名患有免疫性和非免疫性、已治疗和未治疗的血小板减少症患者中对该检测进行了评估。所有血小板计数<100,000/微升的免疫性血小板减少症患者(急性和慢性特发性血小板减少性紫癜以及系统性红斑狼疮)血小板结合IgG水平均升高,86%的患者间接检测结果也呈阳性。所有非免疫性血小板减少症患者血小板相关免疫球蛋白的直接和间接检测结果均正常。在病程中反复接受研究的患者中,发现血小板计数与血小板结合IgG水平呈负相关。系统性红斑狼疮患者对此规则有明显例外。对血小板自身抗体和同种抗体的吸收性研究表明,该检测能够轻易区分这两种抗体类型,还能识别同种抗体的特异性。