Abstract

The performance characteristics of any Anger camera are defined by that camera's spatial and temoral resolutions. Procedures using first-past techniques--such as ejection fraction or left-to-right shunt determinations--require that deadtimes be minimal. We have evaluated a simplified method for measuring a camera's deadtime; it uses a multihole phantom consisting of a lead sheet with 196 holes, 7/16 in. diameter, arranged in a 14 X 14 matrix. Each hole can be filled with a removable lead plug. Count rates are determined following incremental removal of the plugs. Deadtime curves were generated for each of three cameras by this and standard techniques. For each camera, the three curves were virtually identical. Using the phantom, deadtimes could be determined in 15 to 20 min. This phantom provides a simple, rapid, and accurate means of determining camera deadtime and minimizing personnel radiation exposure.

摘要

任何安杰尔相机的性能特征都由该相机的空间分辨率和时间分辨率来定义。使用首次通过技术的程序——比如射血分数或左右分流测定——要求死时间最小。我们评估了一种测量相机死时间的简化方法;它使用一个多孔模体,该模体由一块带有196个直径为7/16英寸的孔的铅板组成,这些孔排列成14×14的矩阵。每个孔都可以用一个可移除的铅塞填充。在逐步移除铅塞后确定计数率。通过这种方法和标准技术为三台相机中的每一台生成了死时间曲线。对于每台相机,这三条曲线几乎是相同的。使用该模体,可以在15到20分钟内确定死时间。这个模体提供了一种简单、快速且准确的确定相机死时间并使人员辐射暴露最小化的方法。