Koppenhöfer E, Schumann H
Pflugers Arch. 1981 Jun;390(3):288-9. doi: 10.1007/BF00658278.
In voltage clamp experiments on myelinated nerve fibres the time resolution of the current measurement is limited by the low-pass characteristics of the internodes. We increased the corner frequency of the current passing internode by grounding one half of this internode externally. Using a simplified equivalent circuit we calculated an increase in the bandwidth of the internode by a factor of about 6. Consequently, the peak value of the recorded capacity current increased while its duration was considerably shortened.
在对有髓神经纤维进行的电压钳实验中,电流测量的时间分辨率受到节间低通特性的限制。我们通过将节间的一半外部接地来提高通过节间的电流的转折频率。使用简化的等效电路,我们计算出节间带宽增加了约6倍。因此,记录的电容电流的峰值增加,而其持续时间则大大缩短。