Suppr超能文献

Hemodynamic changes during fentanyl--oxygen anesthesia for aortocoronary bypass operation.

作者信息

Waller J L, Hug C C, Nagle D M, Craver J M

出版信息

Anesthesiology. 1981 Sep;55(3):212-7. doi: 10.1097/00000542-198109000-00005.

Abstract

Fentanyl in doses of 50-60 microgram/kg has been reported to produce anesthesia with remarkable hemodynamic stability in patients with coronary artery disease (CAD). Because the authors had observed hypertension and tachycardia in response to noxious stimulation during aortocoronary bypass (ACB) operations in patients so anesthetized, they studied the hemodynamic changes and anesthetic conditions produced by fentanyl/O2/relaxant anesthesia in patients undergoing elective ACB. Twelve patients with left ventricular (LV) ejection fractions greater than 0.4 were maintained on propranolol until 10 hours before operation and were premedicated with fentanyl, diazepam, and scopolamine. Cannulae were inserted before the study commenced for measurement of intravascular pressures, arterial blood gases, and thermodilution cardiac output. The patients breathed 100 per cent oxygen throughout the study. Controlled ventilation aided by succinylcholine to reduce truncal rigidity maintained PaCO2 at 30-45 torr. Measurements were made after each of the following: breathing oxygen (control), 10 microgram/kg fentanyl, 50 microgram/kg fentanyl, and 0.1 mg/kg pancuronium, tracheal intubation, skin incision, and sternotomy. Fentanyl alone produced no significant hemodynamic changes. Fentanyl and pancuronium in combination produced increased heart rate and reduced stroke volume. Significant and progressively greater increases in mean arterial pressure and systemic vascular resistance followed intubation, skin incision, and sternotomy. Chest rigidity occurred in every patient at a lower fentanyl dose than did unresponsiveness. While fentanyl, 62.4 +/- 2.9 microgram/kg (SE), produced minor hemodynamic changes, it failed to block hemodynamic responses to noxious stimulation. Such changes resulted in increased cardiac work, and could have affected myocardial oxygen balance unfavorably. In eight of the 12 patients, following the last set of measurements, supplementary anesthetic agents were required to maintain hemodynamic stability during the surgical procedure. The authors suggest that this fentanyl/O2/relaxant technique should be modified for patients with severe CAD and reasonably good LV function.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验