Suppr超能文献

基于抗体捕获法的人血浆中活性肾素和总肾素浓度的微量测定法。

A microassay for active and total renin concentration in human plasma based on antibody trapping.

作者信息

Millar J A, Leckie B J, Morton J J, Jordan J, Tree M

出版信息

Clin Chim Acta. 1980 Feb 14;101(1):5-15. doi: 10.1016/0009-8981(80)90050-9.

Abstract

We have developed and validated a new enzyme-kinetic method for measurement of renin concentration (PRC) in human plasma, based on radioimmunoassay of angiotensin I generated during incubation of plasma and excess sheep or ox renin substrate. Angiotensin I breakdown during incubation is prevented by the presence of anti-angiotensin I serum. The assya does not require prior extraction of renin, is technically simple, and is sufficiently sensitive to measure subnormal renin levels. With minor modifications both "active and "total" renin may be measured. Assay results have been calibrated with the International Standard Renin. PRC measured by this technique correlates significantly with angiotensin I and II, plasma renin activity, and with the PRC method previously used by us.

摘要

我们已经开发并验证了一种新的酶动力学方法,用于测量人血浆中的肾素浓度(PRC)。该方法基于对血浆与过量绵羊或牛肾素底物孵育过程中产生的血管紧张素I进行放射免疫测定。抗血管紧张素I血清的存在可防止孵育过程中血管紧张素I的分解。该测定方法不需要预先提取肾素,技术操作简单,灵敏度足以测量低于正常水平的肾素。稍作修改后,即可测量“活性”和“总”肾素。测定结果已根据国际标准肾素进行校准。用该技术测得的PRC与血管紧张素I和II、血浆肾素活性以及我们之前使用的PRC方法显著相关。