Abstract

The median as well as the ulnar nerve may be used effectively in the evaluation of neuromuscular blockade with the peripheral nerve stimulator. Both ulnar and median nerve stimulation produce flexion of the fingers. For maximum neural stimulation either during the routine use of the peripheral nerve stimulator or when it is used as an aid to peripheral nerve block, the negative pole should be attached to the exploring needle or over the nerve to be stimulated.

摘要

正中神经和尺神经均可有效地用于通过外周神经刺激器评估神经肌肉阻滞。刺激尺神经和正中神经均会引起手指屈曲。在常规使用外周神经刺激器或用作外周神经阻滞辅助手段时,为实现最大程度的神经刺激,负极应连接至穿刺针或待刺激神经上方。