Quin J W, Giannikos J, Robertson P, Hand S J
J Immunol Methods. 1980;34(3):217-24. doi: 10.1016/0022-1759(80)90048-4.
A simple radioactive binding assay for the detection of rheumatoid factor (RF-RBA) is described. Test sera are complement inactivated by incubation in 0.13 M ethylene diaminetetraacetic acid (EDTA) at 37 degrees C and then incubated with 125I-labelled heat-aggregated IgG. Rheumatoid factor bound, labelled IgG is separated from free by precipitation with 2.5% (w/v) polyethylene glycol 6000. Sera from 78 patients and 24 controls were tested in the RF-RBA assay and the results compared with those obtained by the rheumatoid latex test and the rheumaton test. 37 sera were positive and 59 sera were negative for rheumatoid factor by the 3 methods used. A positive correlation (r = 0.56, P less than 0.01) was observed between the rheumaton titre and the RF-RIA result.
本文描述了一种用于检测类风湿因子的简单放射性结合试验(RF-RBA)。将测试血清在37℃下于0.13M乙二胺四乙酸(EDTA)中孵育以使其补体失活,然后与125I标记的热聚集IgG孵育。结合类风湿因子的标记IgG通过用2.5%(w/v)聚乙二醇6000沉淀与游离的IgG分离。对78例患者和24例对照的血清进行了RF-RBA试验,并将结果与类风湿乳胶试验和风湿因子试验所得结果进行比较。在所使用的3种方法中,37份血清类风湿因子呈阳性,59份血清呈阴性。在风湿因子滴度与RF-RIA结果之间观察到正相关(r = 0.56,P<0.01)。