Speros P, Price J
Surv Ophthalmol. 1981 Jan-Feb;25(4):237-52. doi: 10.1016/0039-6257(81)90093-x.
The oscillatory potentials seem to reflect severe disturbances in the retinal (and perhaps choroidal) circulation. In some cases of diabetic retinopathy with severe microangiopathy, the oscillatory potentials may be selectively reduced or extinguished while the amplitude of the a- and b-waves of the ERG remains normal. A correlation appears to exist between severely reduced oscillatory potentials and a circulatory deficiency in the retina. This selective reduction of the oscillatory potentials during advancing retinopathy is considered to be indirect evidence that they are generated independently from the mechanism producing the primary components (the a- and b-waves). The usefulness of the oscillatory potentials in the prognosis of retinal disease, particularly in diabetic retinopathy, is reviewed. The historical background, the techniques and instrumentation necessary to produce and record them, the experimental data available on the site of their origin, the clinical significance to date and the experimental efforts in our laboratory are summarized.
振荡电位似乎反映了视网膜(可能还有脉络膜)循环的严重紊乱。在一些伴有严重微血管病变的糖尿病视网膜病变病例中,振荡电位可能会选择性降低或消失,而视网膜电图的a波和b波振幅仍保持正常。振荡电位严重降低与视网膜循环不足之间似乎存在相关性。在进行性视网膜病变过程中振荡电位的这种选择性降低被认为是它们独立于产生主要成分(a波和b波)的机制而产生的间接证据。本文综述了振荡电位在视网膜疾病预后评估中的作用,特别是在糖尿病视网膜病变中的作用。总结了其历史背景、产生和记录所需的技术与仪器、关于其起源部位的现有实验数据、迄今为止的临床意义以及我们实验室的实验研究工作。