Suppr超能文献

[直线加速器全身照射情况下的剂量测定(作者译)]

[Dosimetry in case of whole-body irradiations with a linear accelerator (author's transl)].

作者信息

Roth J

出版信息

Strahlentherapie. 1981 Oct;157(10):653-7.

PMID:7029791
Abstract

The described whole-body irradiations are effected in order to prepare patients with acute myeloic leukemia for bone marrow transplantation. The patient is irradiated with equal doses from the right and the left side. So a dose of 10 Gy in the middle of the body is achieved which is determined individually by means of phantom measurements. In order to avoid the risk of an interstitial pneumonitis, the lung region is temporarily blinded in such a way that a dose of 8 Gy is obtained there in the middle of the body. During the irradiations, the accumulated dose is measured in different body regions with thermoluminescence dosimeters, a semi-conductor diode and, eventually, a ionization chamber. The scattering width is +/- 13%. We do our best to make the patient's position as comfortable as possible.

摘要

进行所述的全身照射是为了使急性髓性白血病患者为骨髓移植做好准备。患者从右侧和左侧接受等量照射。这样在身体中部可达到10 Gy的剂量,该剂量通过体模测量单独确定。为避免间质性肺炎的风险,肺部区域通过特定方式进行临时遮挡,以使身体中部该区域的剂量为8 Gy。在照射过程中,使用热释光剂量计、半导体二极管以及最终的电离室在身体不同区域测量累积剂量。散射宽度为±13%。我们尽最大努力使患者的体位尽可能舒适。