• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Comparative evaluation of impedance cardiographic and dye dilution methods in determining hemodynamic indices].

作者信息

Kaloianova A

出版信息

Vutr Boles. 1981;20(4):93-8.

PMID:7029910
Abstract

The norms of cardiac output and general peripheral resistance in 81 healthy subjects were determined by impedance-cardiography. The same hemodynamic indices were also studied in 150 patients with ischemic heart disease, idiopathic myocardiopathies, hypertonic disease and acquired valvular diseases in a state of compensation or cardiac insufficiency. The methods of impedance-cardiography and dye dilution were used. A high correlation dependence was found between the results, obtained by the two methods. Discrepancies in the individual results were observed only in the cases with mitral and aortic insufficiency combined mitral and mitral-aortic valvular defects. The author recommends the impedance-cardiography as a reliable method for a wide application in the clinical practice.

摘要

相似文献

1
[Comparative evaluation of impedance cardiographic and dye dilution methods in determining hemodynamic indices].
Vutr Boles. 1981;20(4):93-8.
2
[Comparative evaluation of the cardiac stroke and minute volumes by impedance cardiography and radiocardiography].[通过阻抗心动图和放射心动图对心搏量和每分输出量的比较评估]
Vutr Boles. 1980;19(5):28-33.
3
[Physical work capacity and left ventricular function assessed using an impedance cardiographic method in patients with a rheumatic mitral valve defect].[采用阻抗心动图法评估风湿性二尖瓣缺损患者的体力工作能力和左心室功能]
Vutr Boles. 1989;28(1):36-41.
4
[The dependability of noninvasive stroke volume measurements with impedance cardiography].[阻抗心动图无创测量每搏输出量的可靠性]
Acta Med Austriaca. 1978;5(4-5):118-21.
5
[Mechano- and impedance cardiography parameters in patients with heart failure in administration of a calcium antagonist. The significance of the Heather index].[心力衰竭患者服用钙拮抗剂时的机械性和阻抗心动图参数。希瑟指数的意义]
Z Kardiol. 1989 Mar;78(3):181-6.
6
[Comparative evaluation between the impedance method and the Fick method for determining cardiac minute volume].[阻抗法与菲克法测定心输出量的比较评估]
Vutr Boles. 1980;19(6):46-9.
7
A comparison between the transthoracic electrical impedance method and the direct Fick and the dye dilution methods for cardiac output measurements in man.
Scand J Clin Lab Invest. 1979 Oct;39(6):585-90. doi: 10.3109/00365517909108837.
8
[Dye and thermo dilution method, and impedancecardiography (author's transl)].[染料及热稀释法与阻抗心动描记术(作者译)]
Rinsho Byori. 1979;27(4):278-85.
9
[Radiocardiographic assessment of hemodynamics in different types of acquired heart valve defects].
Vutr Boles. 1986;25(3):91-9.
10
Impedance cardiography for the assessment of cardiac function during exercise.
Jpn Circ J. 1979 Mar;43(3):215-23. doi: 10.1253/jcj.43.215.