• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

穿透性角膜移植术中使用11-0尼龙缝线相关的并发症。

Complications associated with running 11-0 nylon suture in penetrating keratoplasty.

作者信息

Olson R J

出版信息

Ophthalmic Surg. 1982 Jul;13(7):558-61.

PMID:7050808
Abstract

In a series of 100 penetrating keratoplasties, an 11-0 nylon suture was placed after first running a 10-0 suture. Three suture-related complications presented. One complication resulted from inadvertently cutting the 11-0 nylon as the 10-0 nylon was removed. The second complication was that of a traumatic rupture of the 11-0 nylon, which occurred ten months after surgery. The third complication arose from exposure of the 11-0 nylon through the epithelium due to wound contracture. The management of each suture-related complication is discussed.

摘要

在一系列100例穿透性角膜移植术中,先缝一根10-0缝线,然后放置一根11-0尼龙缝线。出现了3例与缝线相关的并发症。一例并发症是在拆除10-0尼龙缝线时不慎切断了11-0尼龙缝线。第二例并发症是11-0尼龙缝线在术后10个月发生外伤性断裂。第三例并发症是由于伤口挛缩,11-0尼龙缝线暴露于上皮表面。文中讨论了每例与缝线相关并发症的处理方法。

相似文献

1
Complications associated with running 11-0 nylon suture in penetrating keratoplasty.穿透性角膜移植术中使用11-0尼龙缝线相关的并发症。
Ophthalmic Surg. 1982 Jul;13(7):558-61.
2
Complications of Mersilene sutures in penetrating keratoplasty.梅氏尼龙缝线在穿透性角膜移植术中的并发症
Refract Corneal Surg. 1992 Jul-Aug;8(4):296-305.
3
Comparison of suturing techniques in keratoplasty for keratoconus.
Ann Ophthalmol. 1975 Mar;7(3):433-6.
4
Results of a double running suture in penetrating keratoplasty performed on keratoconus patients.
Ophthalmic Surg. 1985 Dec;16(12):779-86.
5
Astigmatism after mersilene and nylon suture use for penetrating keratoplasty.用于穿透性角膜移植术的丝裂霉素和尼龙缝线术后散光
Cornea. 2006 Jul;25(6):691-4. doi: 10.1097/01.ico.0000208821.32614.49.
6
Mersilene sutures for corneal surgery.
Ophthalmic Surg. 1995 Mar-Apr;26(2):117-20.
7
Comparison of deep lamellar keratoplasty and penetrating keratoplasty in patients with keratoconus.圆锥角膜患者深层板层角膜移植术与穿透性角膜移植术的比较
Ophthalmology. 2004 Sep;111(9):1676-82. doi: 10.1016/j.ophtha.2004.02.010.
8
Comparison of complication rates and postoperative astigmatism between nylon and mersilene sutures for corneal transplants in patients with Fuchs endothelial dystrophy.富克斯内皮营养不良患者角膜移植中尼龙缝线与涤纶缝线的并发症发生率及术后散光比较。
Cornea. 2006 Jun;25(5):533-9. doi: 10.1097/01.ico.0000214218.60249.e5.
9
[Suturing technic in penetrating keratoplasty--comparative study].
Klin Monbl Augenheilkd. 1980 Jan;176(1):98-102. doi: 10.1055/s-2008-1057409.
10
Loosening of single versus double running sutures in penetrating keratoplasty for keratoconus.圆锥角膜穿透性角膜移植术中单连续缝线与双连续缝线的松动情况
Graefes Arch Clin Exp Ophthalmol. 1999 Jun;237(6):522-3. doi: 10.1007/s004170050273.