The evidence of the pentagastrin rapid test inaugurated by Johnston and Jepson in contrast to the usual analysis of the gastric secretion (DAB 7 GDR) was controlled on altogether 256 patients. Of them 121 patients were examined according to the well-known method and 135 patients with the shortened pentagastrin test. The same efficiency could be verified for the pentagastrin rapid test. The stimulated acid secretion may be sufficiently exactly established with the help of this test for the daily practice and may be recommended for the use in the outpatient practice. The limits of the normal values established up to the existence of a sufficiently large number of test persons, a norm region of 3-25 mmol/h should be taken as a basis.
与通常的胃分泌分析方法(DAB 7 GDR)相比,约翰斯顿和杰普森开创的五肽胃泌素快速检测方法,在总共256例患者身上进行了对照研究。其中121例患者按照知名方法进行检查,135例患者采用缩短的五肽胃泌素检测法。五肽胃泌素快速检测法具有同样的有效性。借助该检测法,在日常实践中可以足够准确地确定刺激后的胃酸分泌情况,因此推荐在门诊实践中使用。在有足够多检测对象之前所确定的正常值范围,应以3 - 25 mmol/h的正常区域为依据。