Suppr超能文献

人体等张姿势保持过程中,纺锤体传入单位放电率对负荷大小的依赖性。

The dependence of discharge rate of spindle afferent units on the size of the load during isotonic position holding in man.

作者信息

Vallbo A B, Hulliger M

出版信息

Brain Res. 1982 Apr 15;237(2):297-307. doi: 10.1016/0006-8993(82)90443-7.

Abstract

The impulse discharge in single afferent units from muscle spindles was recorded in waking human subjects, using tungsten needle electrodes which were percutaneously inserted in the radial nerve. Eighteen spindle afferents from the finger extensor muscles were studied, 11 primaries and 7 secondaries. The subjects performed standardized trapezoidal finger movements in a visual tracking task which included periods of position holding. A load of constant torque opposed finger extension. Its size was varied with successive tests and covered up to 29% of the maximum voluntary contraction force (MVF). The mean discharge of the afferent unit during holding was measured and related to the size of the load. The mean discharge rate of both primary and secondary units increased with the size of the load. There was considerable scatter of the data points, but generally a linear relationship was an acceptable describing function. For the pooled data of the total sample of primaries the slope was 0.47 impulses/s/%MVF, whereas the corresponding figure for the secondaries was 0.66 impulses/s/%MVF after an appropriate correction for a sampling bias. The rates of discharge of the present sample of units were generally low in relation to those reported for afferents from, for instance, ankle muscles in the cat. The rise of spindle discharge with increasing size of the load indicated that a broad parallelism of skeleto- and fusimotor activity was present during accurate position holding. However, there were indications that a rigid linkage between total skeletomotor activity and the fusimotor drive to individual spindles was not present.

摘要

在清醒的人类受试者中,使用经皮插入桡神经的钨针电极记录了来自肌梭的单个传入单位的冲动发放。研究了来自手指伸肌的18个肌梭传入纤维,其中11个为初级传入纤维,7个为次级传入纤维。受试者在视觉跟踪任务中进行标准化的梯形手指运动,该任务包括位置保持期。一个恒定扭矩的负荷对抗手指伸展。其大小在连续测试中变化,覆盖了高达最大自主收缩力(MVF)的29%。测量了传入单位在保持期间的平均发放,并将其与负荷大小相关联。初级和次级单位的平均发放率均随负荷大小增加。数据点有相当大的离散,但总体上线性关系是一个可接受的描述函数。对于初级传入纤维总样本的汇总数据,斜率为0.47脉冲/秒/%MVF,而对于次级传入纤维,在对采样偏差进行适当校正后,相应数字为0.66脉冲/秒/%MVF。与例如猫的踝关节肌肉传入纤维所报告的发放率相比,本样本单位的发放率普遍较低。随着负荷大小增加,肌梭发放的增加表明在精确位置保持期间存在骨骼肌和梭内肌活动的广泛平行性。然而,有迹象表明总骨骼肌活动与对单个肌梭的梭内肌驱动之间不存在刚性联系。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验