Tam G K, Lacroix G
J Assoc Off Anal Chem. 1982 May;65(3):647-50.
A dry ashing, flameless atomic absorption spectrometric method was evaluated to determine arsenic and selenium in foods. Samples were dry-ashed with Mg(NO3)2-MgO and dissolved in HCl. Selenate was reduced to selenite by boiling in 4N HCl. Selenate was reduced to selenite by boiling in 4N HCl, and arsenate to arsenite by treatment with KI. Hydrides of arsenic and selenium were generated by the addition of NaBH4 and were swept by nitrogen and hydrogen into a thermally heated silicate tube furnace. The detection limit was about 5 ppb for each element based on a 10 g sample. Analytical results obtained for several samples of NBS reference materials agreed with the certified values. The procedure was evaluated by another laboratory and results were satisfactory.
评估了一种干灰化无火焰原子吸收光谱法来测定食品中的砷和硒。样品用硝酸镁 - 氧化镁进行干灰化并溶于盐酸。通过在4N盐酸中煮沸,将硒酸盐还原为亚硒酸盐;通过用碘化钾处理,将砷酸盐还原为亚砷酸盐。加入硼氢化钠生成砷和硒的氢化物,并用氮气和氢气吹扫至热加热的硅酸盐管炉中。基于10克样品,每种元素的检测限约为5 ppb。对几种NBS标准物质样品获得的分析结果与认证值相符。该方法由另一个实验室进行评估,结果令人满意。