Honda Y, Kawano S, Negi A, Koizumi K
Ophthalmic Surg. 1982 May;13(5):387-91.
A balloon sensor was implanted in the posterior wall of the rabbit eye, and pressure fluctuation during several surgical procedures was monitored. Temporary IOP increase during digital massage sometimes reached near 100 mm Hg. Pressure increase during incision on the cornea was quite high, while corneal suturing, lens extraction, iridectomy, and open-sky vitrectomy induced minor fluctuating pressure on the posterior wall. Diathermy coagulation and scleral incision during simulated retinal detachment surgery increased IOP, exceeding 50 mm Hg and sometimes reaching 100 mm Hg.
将一个气球传感器植入兔眼后壁,并监测了几个外科手术过程中的压力波动情况。指压按摩期间眼压暂时升高有时接近100毫米汞柱。角膜切开时压力升高相当高,而角膜缝合、晶状体摘除、虹膜切除术和开放式玻璃体切除术在后壁引起轻微的压力波动。模拟视网膜脱离手术期间的透热凝固和巩膜切开会使眼压升高,超过50毫米汞柱,有时达到100毫米汞柱。