Martin D K, Holden B A
Am J Optom Physiol Opt. 1982 May;59(5):436-41. doi: 10.1097/00006324-198205000-00011.
An in vivo method of measuring the size of the human cornea by using catoptric imagery as devised for both closed-circuit television and 35-mm camera systems. The system was validated by using precision reticules and casts of eyes. The reproducibility of the closed-circuit television system was +/- 0.11 mm. The mean horizontal corneal diameter (HCD) for a sample of the right eyes of 50 subjects was 12.89 +/- 0.60 mm. The system was also used to measure horizontal visible iris diameter (HVID). The mean HVID for the same sample was 11.64 +/- 0.49 mm. Although there was a good general correlation between HCD and HVID, the HVID was found to be a poor predictor of HCD for the individual eye.