一种测量人眼角膜活体直径的新方法。

A new method for measuring the diameter of the in vivo human cornea.

作者信息

Martin D K, Holden B A

出版信息

Am J Optom Physiol Opt. 1982 May;59(5):436-41. doi: 10.1097/00006324-198205000-00011.

Abstract

An in vivo method of measuring the size of the human cornea by using catoptric imagery as devised for both closed-circuit television and 35-mm camera systems. The system was validated by using precision reticules and casts of eyes. The reproducibility of the closed-circuit television system was +/- 0.11 mm. The mean horizontal corneal diameter (HCD) for a sample of the right eyes of 50 subjects was 12.89 +/- 0.60 mm. The system was also used to measure horizontal visible iris diameter (HVID). The mean HVID for the same sample was 11.64 +/- 0.49 mm. Although there was a good general correlation between HCD and HVID, the HVID was found to be a poor predictor of HCD for the individual eye.

摘要

一种通过使用专为闭路电视和35毫米相机系统设计的反射成像来测量人眼角膜大小的体内方法。该系统通过使用精密标线片和眼球模型进行了验证。闭路电视系统的重现性为±0.11毫米。50名受试者右眼样本的平均水平角膜直径(HCD)为12.89±0.60毫米。该系统还用于测量水平可见虹膜直径(HVID)。同一样本的平均HVID为11.64±0.49毫米。尽管HCD和HVID之间存在良好的总体相关性,但发现HVID对单眼HCD的预测效果不佳。