A comparative study of platelet count and platelet volume distribution was performed on whole blood (Coulter counter S+) or platelet rich plasma (Thrombo Coulter and Coulter ZBI + Channelyser C 1 000). With the exception of severe thrombocytopenia the results of platelet counts obtained with the coulter S + were very reproducible (CV less than 4%) and a good correlation was observed between results obtained on whole blood and on platelet rich plasma (PRP). The mean platelet volume (MPV) was significantly higher in whole blood than in PRP, but the difference was very slight, suggesting that platelet volume distribution in PRP and in whole blood are similar. In whole blood collected in EDTA MPV increased significantly during the 2 hours after blood collection and then reached a plateau. This finding underlines the need for a standard technique. Preliminary results obtained with the Coulter S + in 86 diabetic patients and in 73 unselected control subjects demonstrated a significant increase of MPV and of the index of platelet distribution (IDP) given by the apparatus, without modification of platelet count in diabetics. These results could suggest a compensated increased platelet consumption in the circulating blood.
对全血(库尔特计数器S +)或富血小板血浆(血栓库尔特计数器和库尔特ZBI +通道分析仪C 1000)进行了血小板计数和血小板体积分布的比较研究。除严重血小板减少症外,使用库尔特S +获得的血小板计数结果具有很高的重复性(变异系数小于4%),并且在全血和富血小板血浆(PRP)上获得的结果之间观察到良好的相关性。全血中的平均血小板体积(MPV)显著高于PRP,但差异非常小,表明PRP和全血中的血小板体积分布相似。在EDTA抗凝的全血中,采血后2小时内MPV显著增加,然后达到平台期。这一发现强调了标准技术的必要性。使用库尔特S +在86例糖尿病患者和73例未选择的对照受试者中获得的初步结果表明,糖尿病患者的MPV和仪器给出的血小板分布指数(IDP)显著增加,而血小板计数没有改变。这些结果可能提示循环血液中血小板消耗增加得到了代偿。