Suppr超能文献

针对样本移除对灌注液浓度进行校正。

Correction of perfusate concentration for sample removal.

作者信息

Hayton W L, Chen T

出版信息

J Pharm Sci. 1982 Jul;71(7):820-1. doi: 10.1002/jps.2600710726.

Abstract

Repeated sampling of a drug solution that is recirculated through a perfused body increases the rate of drug disappearance from the perfusate. When the volume of the drug solution (VT) is maintained constant by addition of drug-free perfusate after sampling, the measured drug concentration (Ci) can be corrected for drug removed in previous samples by using the equation C'i = CiVTC'i-1/(VT - VS)Ci-1, where C'i is the corrected drug concentration in the ith sample, VS is the volume of the sample, and C'1 = C1. An error in an particular Ci is not transmitted to a subsequent C'i value. The method can be used when the time interval between samples and when VS vary from sample to sample, but return of the drug from the perfused body to the perfusate after sampling may cause C'i to be overestimated.

摘要

对通过灌注体循环的药物溶液进行重复采样会增加药物从灌注液中消失的速率。当通过在采样后添加无药物灌注液使药物溶液体积(VT)保持恒定时,可使用公式C'i = CiVTC'i-1/(VT - VS)Ci-1对测量的药物浓度(Ci)进行校正,以补偿先前样本中去除的药物,其中C'i是第i个样本中的校正药物浓度,VS是样本体积,且C'1 = C1。特定Ci中的误差不会传递到后续的C'i值。当样本之间的时间间隔以及VS在不同样本之间变化时,该方法仍可使用,但采样后药物从灌注体返回灌注液可能会导致C'i被高估。