Akriotis V J, Arbus G S
Nephron. 1982;31(2):180-1. doi: 10.1159/000182640.
The feasibility of room temperature incubation of Microstix-3 specimens to detect urinary tract infection was studied. This procedure, if successful, would allow home monitoring of patients and eliminate the need for an incubator. Four Microstix-3 strips were dipped into each of 1,241 urine specimens and incubated at 18, 22, 27 or 37 degree C. Results after incubation for 24 h at 27 degree C and after 48 h at 22 degree C were comparable to those after incubation for 18-24 h at 37 degree C. However, even after 72 h, incubation at 18 degree C did not produce results comparable to those obtained at 37 degree C. It appears that the incubator can be successfully eliminated at the higher temperatures tested if the limits of time outlined are observed.
研究了Microstix - 3标本在室温下孵育以检测尿路感染的可行性。如果该程序成功,将允许对患者进行家庭监测并消除对培养箱的需求。将四条Microstix - 3试纸条浸入1241份尿液标本中的每一份,并在18、22、27或37摄氏度下孵育。在27摄氏度下孵育24小时后以及在22摄氏度下孵育48小时后的结果与在37摄氏度下孵育18 - 24小时后的结果相当。然而,即使在72小时后,在18摄氏度下孵育也未产生与在37摄氏度下获得的结果相当的结果。看来,如果遵守规定的时间限制,在测试的较高温度下可以成功地不使用培养箱。