Gear A R, Burke D
Blood. 1982 Nov;60(5):1231-4.
The platelet release reaction was studied by a new quenched-flow approach. Platelets labeled with 14C-serotonin were reacted for short times (up to 5 sec) with thrombin and then quenched with glutaraldehyde or paraformaldehyde. Serotonin secretion began within 1 sec and was nearly complete by 4 sec. Aggregation recorded by a resistive-particle counter was similarly fast. Therefore, the quenched-flow system reveals that serotonin secretion can occur more rapidly than estimated in earlier studies.
采用一种新的淬灭流动方法研究了血小板释放反应。用14C - 5 -羟色胺标记的血小板与凝血酶短时间(最长5秒)反应,然后用戊二醛或多聚甲醛淬灭。5 -羟色胺分泌在1秒内开始,4秒时几乎完成。用电阻颗粒计数器记录的聚集同样很快。因此,淬灭流动系统表明5 -羟色胺分泌比早期研究估计的要快得多。