Suppr超能文献

次声对大鼠转棒式跑步机运动能力的影响。

Effects of infrasound on the rota-rod treadmill performance of rats.

作者信息

Yamamura K, Kishi R

出版信息

Eur J Appl Physiol Occup Physiol. 1980;45(1):81-6. doi: 10.1007/BF00421204.

Abstract

The present study was designed to evaluate the effects of infrasound on behavioral performance in rats. The rats were divided into two groups, one selected for good performance (six rats: superior group) and the other for poor performance (six rats: inferior group) on the Rota-rod Treadmill. Exposure conditions were as follows: Exp. 1 Control (150 min), Exp. 2 Exposure to infrasound with a main frequency of 16 Hz and a sound pressure level of 105 dB (S.P.L.) (70 min), Exp. 3 Exposure to infrasound with a main frequency of 16 Hz and a sound pressure level of 95 dB (S.P.L.) (70 min), Exp. 4 Exposure infrasound with a main frequency of 16 Hz and a sound pressure level of 85 dB (S.P.L.) (150 min), Exp. 5 Exposure to infrasound with a main frequency of 16 Hz and a sound pressure level of 75 dB (S.P.L.) (150 min), Exp. 6 Exposure to Pink Noise of 72 dB (A) (70 min). Comparison of the pre-exposure endurance time (Maximum: 2 min) on the Rota-Rod Treadmill with endurance after exposure to infrasound showed that the endurance time of the superior group after exposure to 16 Hz, 105 dB was not reduced. The endurance of the inferior group was reduced by exposure to 16 Hz, 105 dB after 10 min, to 16 Hz, 95 dB after 70 min, and to 16 Hz, 85 dB after 150 min.

摘要

本研究旨在评估次声对大鼠行为表现的影响。将大鼠分为两组,一组在转棒式跑步机上表现良好(六只大鼠:优组),另一组表现不佳(六只大鼠:劣组)。暴露条件如下:实验1为对照(150分钟),实验2为暴露于主频16Hz、声压级105dB(声压水平)(70分钟),实验3为暴露于主频16Hz、声压级95dB(声压水平)(70分钟),实验4为暴露于主频16Hz、声压级85dB(声压水平)(150分钟),实验5为暴露于主频16Hz、声压级75dB(声压水平)(150分钟),实验6为暴露于72dB(A)的粉红噪声(70分钟)。比较转棒式跑步机上暴露前的耐力时间(最长:2分钟)与暴露于次声后的耐力,结果显示,优组暴露于16Hz、105dB后耐力时间未降低。劣组在暴露于16Hz、105dB 10分钟后、暴露于16Hz、95dB 70分钟后以及暴露于16Hz、85dB 150分钟后耐力降低。

相似文献

1
Effects of infrasound on the rota-rod treadmill performance of rats.
Eur J Appl Physiol Occup Physiol. 1980;45(1):81-6. doi: 10.1007/BF00421204.
2
[Effects of infrasound on visual electrophysiology in mice].
Space Med Med Eng (Beijing). 2003 Apr;16(2):115-9.
4
[The effects of infrasound on the blood coagulation function of guinea pigs].
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi. 2011 Mar;29(3):209-11.
6
Effects of infrasound on cognitive performance.
Aviat Space Environ Med. 1978 Apr;49(4):582-6.
7
Infrasound increases intracellular calcium concentration and induces apoptosis in hippocampi of adult rats.
Mol Med Rep. 2012 Jan;5(1):73-7. doi: 10.3892/mmr.2011.597. Epub 2011 Sep 23.
9
Effect of infrasound on cochlear damage from exposure to a 4 kHz octave band of noise.
Hear Res. 2007 Mar;225(1-2):128-38. doi: 10.1016/j.heares.2007.01.016. Epub 2007 Jan 19.

本文引用的文献

1
A note on a simple apparatus for detecting neurological deficit in rats and mice.
J Am Pharm Assoc Am Pharm Assoc. 1957 Mar;46(3):208-9. doi: 10.1002/jps.3030460322.
2
Effect of acrylamide on rotarod performance and sciatic nerve -glucuronidase activity of rats.
Toxicol Appl Pharmacol. 1972 Jun;22(2):259-68. doi: 10.1016/0041-008x(72)90176-7.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验