Soldin S J, Lam G, Pollard A, Allen L C, Logan A G
Clin Biochem. 1980 Dec;13(6):285-91. doi: 10.1016/s0009-9120(80)80011-7.
We have developed an high performance liquid chromatographic procedure employing amperometric detection for the measurement of urinary free norepinephrine, epinephrine and dopamine. The between-day precision (C.V.) at various concentrations of the above analytes varied from 4.8-11.6%. There was negligible between-urine difference in the percent recovery of norepinephrine and epinephrine but considerable between-urine difference for dopamine. The procedure has been used to determine reference ranges in infants, children and adults. Its preliminary application to the laboratory detection of neural crest tumors is also described.
我们开发了一种采用安培检测的高效液相色谱法,用于测定尿中游离去甲肾上腺素、肾上腺素和多巴胺。上述分析物在不同浓度下的日间精密度(变异系数)为4.8 - 11.6%。去甲肾上腺素和肾上腺素的回收率在不同尿液之间差异可忽略不计,但多巴胺在不同尿液之间存在显著差异。该方法已用于确定婴儿、儿童和成人的参考范围。还描述了其在神经嵴肿瘤实验室检测中的初步应用。