Tobioka H, Kawashima R
J Assoc Off Anal Chem. 1978 Sep;61(5):1054-7.
A gas-liquid chromatographic (GLC) method with electron capture detection was developed for determining hexestrol residues based on a GLC method for diethylstilbestrol residues. The extraction and purification procedures were based on a published procedure. Pentafluoropropionic (PFP) and heptafluorobutyric (HFB) anhydrides and other halogenated compounds were compared as acylation reagents. PFP anhydride was selected because it provided reproducible GLC responses. Of the 3 column packing materials tested, OV-17, OV-210, and QF-1, OV-17 was the most stable under the GLC conditions used. A pH 10.5--10.6 in the purification step gave higher recoveries than pH 10.3 or pH 10.8 and was selected for use. The method is suitable for determining residues of 0.5 ppb. The limit of sensitivity ranges from 0.1 to 0.2 ppb.
在一种已发表的己烯雌酚残留量气相色谱法的基础上,开发了一种带电子捕获检测的气液色谱(GLC)法来测定己烷雌酚残留量。提取和纯化程序基于已发表的方法。对五氟丙酸(PFP)酐、七氟丁酸(HFB)酐及其他卤代化合物作为酰化试剂进行了比较。选择PFP酐是因为它能提供可重现的GLC响应。在所测试的3种柱填充材料OV-17、OV-210和QF-1中,OV-17在所用的GLC条件下最稳定。纯化步骤中pH 10.5-10.6的回收率高于pH 10.3或pH 10.8,因此选择该pH值用于实际操作。该方法适用于测定0.5 ppb的残留量。灵敏度极限范围为0.1至0.2 ppb。