Toxicological analysis of phenylethylamines by high performance reversed-phase ion-pair partition thin-layer and liquid chromatographies.

作者信息

Verbiese-Genard N, van Damme M, Hanocq M, Molle L

出版信息

Clin Toxicol. 1981 Apr;18(4):391-400. doi: 10.3109/15563658108990262.

Abstract

A rapid and specific method was developed to identify phenylethylamines in urine. After an organic extraction at appropriate pH, reverse phase ion-pair partition chromatographies were used: a high performance thin-layer test followed by high performance liquid chromatography. The use and benefits of the procedure are described in detail and compared with other methods. In a very short time (10 min) the presence of phenylethylamine is detected on a thin-layer plate. In the case of positive result the product is then specifically identified by high performance liquid chromatography by means of a complete UV spectrum traced directly on the eluated compound. The sensitivity of the method is highly increased because the detection is operated at 215 nm.