Abstract

A flicker sensitivity test based on measuring modulation thresholds for light varying sinusoidally with time around two mean scotopic luminances was performed on 21 female patients heterozygous for X-linked retinitis pigmentosa and 22 normal observers. The patients required, on average, 1.5 times the normal modulation to detect flicker over the whole frequency range where thresholds could be measured. The results suggest that the rod system of heterozygotes exhibits a reduced signal-to-noise ratio compared with normal but that the dominant time delays in the signaling process are not significantly altered.

摘要

对21名患有X连锁视网膜色素变性的女性杂合子患者和22名正常观察者进行了闪烁敏感度测试,该测试基于测量在两个平均暗视亮度附近随时间呈正弦变化的光的调制阈值。在整个可测量阈值的频率范围内,患者平均需要正常调制的1.5倍才能检测到闪烁。结果表明,与正常情况相比,杂合子的视杆系统表现出较低的信噪比,但信号传导过程中的主要时间延迟没有显著改变。