• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

羊水的固有荧光。

Intrinsic fluorescence of the amniotic fluid.

作者信息

Leiberman J R, Molcho J, Alsheh N, Sasson F, Cohen A

出版信息

Isr J Med Sci. 1981 Apr;17(4):266-70.

PMID:7239873
Abstract

The intrinsic fluorescence of clear amniotic fluid from third-trimester pregnancy is reported. The fluorescence intensity peaked at 405 nm when excited by ultraviolet light in the range of 310 to 360 nm. All of the 33 samples tested fluoresced, and their emission spectrum had the same shape, varying only in magnitude. Changing sample temperature (20 to 50 C) and sample pH (7.2 to 7.7) had little effect on the emission spectrum. The same fluorescence, with higher intensity, was observed when some newborn urine was tested. The fluorescence of amniotic fluid may provide a new tool to determine fetal age, fetal organ maturation, and fetal distress.

摘要

报道了妊娠晚期清亮羊水的固有荧光。当在310至360nm范围内的紫外光激发时,荧光强度在405nm处达到峰值。所测试的33个样本均发出荧光,且它们的发射光谱形状相同,仅强度有所不同。改变样本温度(20至50℃)和样本pH值(7.2至7.7)对发射光谱影响很小。当测试一些新生儿尿液时,观察到了相同的荧光,但强度更高。羊水的荧光可能为确定胎儿年龄、胎儿器官成熟度和胎儿窘迫提供一种新工具。

相似文献

1
Intrinsic fluorescence of the amniotic fluid.羊水的固有荧光。
Isr J Med Sci. 1981 Apr;17(4):266-70.
2
Intrinsic fluorescence polarization of amniotic fluid: II. Toward a noninvasive method for the determination of fetal lung maturity.羊水的固有荧光偏振:II. 迈向一种用于测定胎儿肺成熟度的非侵入性方法。
Photochem Photobiol. 2006 Nov-Dec;82(6):1591-4. doi: 10.1562/2006-07-27-RA-986.
3
[Secretory immunoglobulin A (S-IgA) in amniotic fluid and in pharyngeal mucus and urine of newborn infants].
Zentralbl Gynakol. 1983;105(2):99-104.
4
Relationship of amniotic fluid lecithin concentration to incidence of respiratory distress; determination by foam stability test with amniotic fluid phosphatidyl glycerol and creatinine as additional indexes of fetal pulmonary maturation.
N Y State J Med. 1980 Aug;80(9):1381-4.
5
Amniotic fluid oestriol concentration during the last trimester of pregnancy. II. Perinatal mortality and morbidity.妊娠晚期羊水雌三醇浓度。II. 围产期死亡率和发病率。
Acta Obstet Gynecol Scand Suppl. 1974;29:29-36.
6
[Oestrogens and cortisol in amniotic fluid of normal and complicated pregnancies (author's transl)].
Z Geburtshilfe Perinatol. 1975 Dec;179(6):437-40.
7
[Various indexes of fetal maturity in the amniotic fluid].
Rev Chil Obstet Ginecol. 1974;39(6):259-67.
8
Meconium does not guarantee fetal lung maturity.胎粪不能保证胎儿肺成熟。
J Matern Fetal Med. 1997 May-Jun;6(3):180-3. doi: 10.1002/(SICI)1520-6661(199705/06)6:3<180::AID-MFM12>3.0.CO;2-M.
9
Amniotic fluid arborization: effect of blood, meconium, and pH alterations.羊水树状化:血液、胎粪及pH值改变的影响
Obstet Gynecol. 1984 Aug;64(2):248-50.
10
[Evaluation of fetal maturity using ultrasonography of the placenta in comparison with analysis of amniotic fluid].[与羊水分析相比,利用胎盘超声检查评估胎儿成熟度]
Jugosl Ginekol Perinatol. 1988 Sep-Dec;28(5-6):107-11.