Sephadex G-100 gel filtration of urine from male Wistar rats revealed 3 protein peaks: peak I (eluted with the void volume of the column), peak II (Mr between 67 000 and 43 000), and peak III (Mr about 13 700). Nephrotoxic compounds were given as a single i.p. injection. Peak I, and especially peak II were significantly increased in 24-h urine samples from rats receiving mercuric acetate (1.58 mg/kg), mercuric trifluoroacetate (MTFA) (2.22 mg/kg), sodium ethylmercurithiosalicylate (EMTSA) (20.2 mg/kg), sodium tetrathionate (250 mg/kg), ammonium fluoride (18.5 mg/kg), paramomycin sulfate (800 mg/kg), ochratoxin A (5 mg/kg) and cis-platinum (4 mg/kg). It is concluded that gel filtration of urine can be used as a method to detect nephrotoxicity in rats.

摘要

对雄性Wistar大鼠的尿液进行葡聚糖G - 100凝胶过滤,结果显示出3个蛋白质峰:峰I(与柱的空体积一起洗脱)、峰II(相对分子质量在67000至43000之间)和峰III(相对分子质量约为13700)。肾毒性化合物通过单次腹腔注射给予。在接受醋酸汞(1.58毫克/千克)、三氟醋酸汞(MTFA)(2.22毫克/千克)、乙基汞硫代水杨酸钠(EMTSA)(20.2毫克/千克)、连四硫酸钠(250毫克/千克)、氟化铵(18.5毫克/千克)、硫酸巴龙霉素(800毫克/千克)、赭曲霉毒素A(5毫克/千克)和顺铂(4毫克/千克)的大鼠的24小时尿液样本中,峰I,尤其是峰II显著增加。得出的结论是,尿液的凝胶过滤可用作检测大鼠肾毒性的一种方法。