We developed a method to estimate an overall open-loop gain of the arterial pressure control system without surgically opening the reflex loop. Dogs anesthetized by intravenous injection of Nembutal (35 mg/kg body wt) were bled by 2 ml/kg body wt within 2-3 s through a catheter inserted into the abdominal aorta. Arterial pressure change after the quick hemorrhage was monitored via a catheter placed in the aortic arch for more than 2 min. The overall open-loop gain of the lumped arterial pressure control system was assessed as (delta API/delta APs)-1, where delta API is the immediate fall and delta APs the steady-state fall in mean arterial pressure obtained by a filter with a 2-s time constant. The advantage of this method is that the overall open-loop gain can be estimated under the closed-loop condition in which the baroreceptor reflexes operate naturally around the existing range of systemic arterial pressure. This enables one to study time-varying characteristics of the reflex gain. The disadvantage is that the substantial constituents of the lumped reflex system remain to be confirmed.

摘要

我们开发了一种无需通过手术打开反射环路就能估算动脉压力控制系统整体开环增益的方法。通过静脉注射戊巴比妥(35毫克/千克体重)麻醉的犬,在2至3秒内通过插入腹主动脉的导管按2毫升/千克体重放血。快速失血后通过置于主动脉弓的导管监测动脉压变化超过2分钟。集总动脉压力控制系统的整体开环增益评估为(ΔAPI/ΔAPS)-1,其中ΔAPI是通过具有2秒时间常数的滤波器获得的平均动脉压的即刻下降值,ΔAPS是稳态下降值。该方法的优点是可以在闭环条件下估算整体开环增益,在此条件下压力感受器反射在现有体循环动脉压范围内自然运作。这使得人们能够研究反射增益的时变特性。缺点是集总反射系统的主要组成部分仍有待确认。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验