Computed tomography for localization of parathyroid adenomas.

作者信息

Whitley N O, Bohlman M, Connor T B, McCrea E S, Mason G R, Whitley J E

出版信息

J Comput Assist Tomogr. 1981 Dec;5(6):812-7. doi: 10.1097/00004728-198112000-00004.

Abstract

Fourteen consecutive patients with the clinical diagnosis of primary hyperparathyroidism had computed tomography (CT) preoperatively to evaluate the use of CT in localizing parathyroid adenomas. The patients were scanned from above the level of the thyroid cartilage to the bifurcation of the trachea. Computed tomography correctly identified, prospectively, the site of the adenoma in 7 of 14 patients, including one adenoma that was ectopic in location. Nine of these patients also had barium esophagrams, and this study was accurate in only three of the nine. Our study suggests that CT may be beneficial in the preoperative localization of parathyroid adenomas, particularly those in ectopic locations.

摘要

连续14例临床诊断为原发性甲状旁腺功能亢进的患者术前行计算机断层扫描(CT),以评估CT在甲状旁腺腺瘤定位中的应用。扫描范围从甲状软骨水平上方至气管分叉处。CT前瞻性地正确识别出14例患者中的7例腺瘤位置,其中包括1例异位腺瘤。这9例患者还进行了食管钡餐造影,而该检查仅在9例中的3例准确显示。我们的研究表明,CT可能有助于甲状旁腺腺瘤的术前定位,尤其是那些异位的腺瘤。