Tabushi K, Itoh S, Watanabe Y, Harada A, Nakajima T, Yamakawa M, Sakura M, Akiyama Y, Sasaki Y, Nagai T
Radioisotopes. 1981 Jun;30(6):318-24.
The characteristics of the motion corrector system attached to LFOV gamma-camera (Searle) was evaluated using a T-shaped plane source and point sources. The random movement without rotation of a T-shaped plane source was successfully corrected. However, rotating motion of the plane source was not corrected. When a point source placed on a rotating table, ring images were obtained. When motion corrector was used, the radius of ring images was increased with the increase of rotating speed and it was decreased with the increase of radioactivity of the source. Line images were obtained when point sources were placed on a shaker, which caused linear periodic motion of the sources. The use of the motion corrector reduced the length of line images.