Long W F
Am J Optom Physiol Opt. 1981 Dec;58(12):1161-73. doi: 10.1097/00006324-198112000-00017.
The accuracy of meridional refraction using equally spaced preselected meridians was investigated by using populations of computer-simulated patients. The number of meridians refracted, patient refractive error, and the coarseness of phoroptor steps were varied. Results indicate that the accuracy of meridional refraction is independent of the relative orientation of the axis of the patient's astigmatism and the preselected meridians, that little is to be gained by use of a phoropter with steps finer than the usual 0.25 D, and that with a sufficient number of meridians, meridional refraction can be as accurate as more conventional techniques.
通过使用计算机模拟患者群体,研究了使用等间距预选子午线进行子午线屈光检查的准确性。屈光检查的子午线数量、患者屈光不正以及验光仪步长的粗细各不相同。结果表明,子午线屈光检查的准确性与患者散光轴与预选子午线的相对方向无关,使用步长比通常的0.25D更精细的验光仪几乎没有什么好处,并且如果有足够数量的子午线,子午线屈光检查可以与更传统的技术一样准确。