动物笼内静电场的时间变化

Temporal variation of the static electric field inside an animal cage.

作者信息

Shigemitsu T, Tsuchida Y, Nishiyama F, Matsumoto G, Nakamura H, Shimizu K

出版信息

Bioelectromagnetics. 1981;2(4):391-402. doi: 10.1002/bem.2250020410.

Abstract

The temporal variation of a static electric field inside an animal cage was investigated with a newly developed small, simple field meter. The field inside the cage was found to be highly dependent on the surface conductivity of the dielectric material. As the surface of the cage became dirty because of animal occupancy, the static electric field inside it became considerably smaller from the moment the field was turned on. Clean cages also modified the static electric field inside them, the field decaying from an initial to a much lower value over several hours. The mechanism of field attenuation for both cases is surface leakage. Surface leakage for a clean cage takes place much more slowly than for a dirty cage. This was confirmed by measuring DC insulation resistance. To examine this phenomenon further, the field in a metal cage width high electrical conductivity was measured. The static electric field inside the metal cage was also found to be reduced. An improved cage design that avoids these problems, is suggested for the study of the biologic effects of static electric fields.

摘要

使用新开发的小型简易电场计对动物笼内静电场的时间变化进行了研究。发现笼内电场高度依赖于介电材料的表面电导率。由于动物居住使笼子表面变脏,从电场开启的那一刻起,笼内的静电场就变得相当小。干净的笼子也会改变其内部的静电场,电场在几个小时内从初始值衰减到低得多的值。两种情况下电场衰减的机制都是表面泄漏。干净笼子的表面泄漏比脏笼子慢得多。通过测量直流绝缘电阻证实了这一点。为了进一步研究这一现象,测量了具有高电导率的金属笼内的电场。还发现金属笼内的静电场有所降低。建议采用一种改进的笼子设计来避免这些问题,用于研究静电场的生物效应。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验