Surface morphology and tensile force at breaking point or different kinds of intravenous catheters before and after usage.

作者信息

Rosenbauer K A, Herzer J A

出版信息

Scan Electron Microsc. 1981(Pt 3):125-30.

PMID:7330573
Abstract

Heads of seven different types of unused and used intravenous catheters as well as tips of the corresponding needles for venipuncture, artificially cut and ruptured surfaces were either directly mounted on stubs or previously fixed in 1% phosphate buffered glutaraldehyde (pH 7.4), dehydrated with acidified 2, 2-dimethoxy-propane, dried in a critical point drying apparatus using CO2, mounted with silver-paint and sputter coated with 20 nm gold. In addition tensile tests of unused catheters were carried out. According to the tensile tests and to the SEM findings neither spontaneous breakage nor manufacturing defects may be reason of catheter embolism. Manufacturing defects at the tips of needles for venipuncture, as well as rough surfaces of the introducers or catheter walls may cause endothelial lesions. Settling of formed elements of the blood apparently is related to ruggedness of the catheter wall or to manufacturing defects. Thrombi, grown on he outer surface of the catheters are very rare. In Cavafix catheters thrombus formation is mostly related to the roughness of radio-opaque parts of the catheter wall. Outgrowth of the thrombus via the top to the outer surface could be demonstrated frequently

摘要

相似文献

1
Surface morphology and tensile force at breaking point or different kinds of intravenous catheters before and after usage.
Scan Electron Microsc. 1981(Pt 3):125-30.
2
Light microscopic and scanning electron microscopic findings on intravenous polyurethane catheters.
Scan Electron Microsc. 1982(Pt 2):765-72.
3
Surface morphology of unused and used Hydromer-coated intravenous catheters.未使用和已使用的Hydromer涂层静脉导管的表面形态。
Scan Electron Microsc. 1986(Pt 1):157-64.
4
Microbial colonization of prosthetic devices. I. Microtopographical characteristics of intravenous catheters as detected by scanning electron microscopy.人工装置的微生物定植。I. 静脉导管微观形貌特征的扫描电子显微镜检测
Zentralbl Bakteriol Mikrobiol Hyg B. 1981;173(5):285-92.
5
Surface characteristics of plastic intravenous catheters.塑料静脉导管的表面特性。
Am J Hosp Pharm. 1979 Dec;36(12):1707-11.
6
Role of catheter surface morphology on intravascular thrombosis of plastic catheters.
J Biomed Mater Res. 1979 May;13(3):459-66. doi: 10.1002/jbm.820130310.
7
Microbial colonization of prosthetic devices. III. Adhesion of staphylococci to lumina of intravenous catheters perfused with bacterial suspensions.假体装置的微生物定植。III. 葡萄球菌对灌注细菌悬液的静脉导管管腔的黏附。
Zentralbl Bakteriol Mikrobiol Hyg B. 1981;173(5):300-7.
8
Roughness and thrombogenicity of the outer surfaces of intravascular catheters.
J Biomed Mater Res. 1985 Apr;19(4):381-95. doi: 10.1002/jbm.820190404.
9
Thrombogenicity of tips of umbilical catheters.脐静脉导管尖端的血栓形成倾向
Pediatrics. 1981 Apr;67(4):467-71.
10
Bacterial adherence to intravenous catheters and needles and its influence by cannula type and bacterial surface hydrophobicity.细菌对静脉内导管和针头的黏附及其受套管类型和细菌表面疏水性的影响。
J Lab Clin Med. 1986 Feb;107(2):136-40.