• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Early results after combined aortic and mitral valve replacement with the convexo-concave Björk-Shiley prosthesis.

作者信息

Aberg B

出版信息

Scand J Thorac Cardiovasc Surg. 1981;15(2):117-21. doi: 10.3109/14017438109101035.

DOI:10.3109/14017438109101035
PMID:7336182
Abstract

This paper reports the early results of combined aortic and mitral valve replacement in 39 patients, who underwent operation with the convexo-concave Björk-Shiley prosthesis. There were no intra-operative deaths. Two patients (5%) died while in hospital of myocardial failure and left ventricular rupture, respectively. One late death (3%) was due to a thrombosis of the mitral prosthesis (N.Y.H.A. class IV at operation). Cumulative follow-up (2-31 months) was 100%. One patient had radial artery embolization while converting to atrial fibrillation. Another patient required repair of an aortic paraprosthetic leakage. Clinical improvement (N.Y.H.A.) was noted in 15/19 re-examined patients (79%). Average heart volume decreased (p less than 0.05) and Maximal working capacity increased (p less than 0.05) after valve replacement. Seven patients (7/19) converted to sinus rhythm after operations and one (1/19) developed atrial arrhythmia. Haemolysis was generally mild and without signs of anaemia. The overall thrombo-embolic rate (5.9% per year) remained thus far the same as that encountered with the standard model prosthesis in combined aortic and mitral valvular disease.

摘要

相似文献

1
Early results after combined aortic and mitral valve replacement with the convexo-concave Björk-Shiley prosthesis.
Scand J Thorac Cardiovasc Surg. 1981;15(2):117-21. doi: 10.3109/14017438109101035.
2
Combined aortic and mitral valve replacement with the Björk-Shiley tilting disc valve prosthesis. Early and late results in 75 consecutive patients.
Scand J Thorac Cardiovasc Surg. 1977;11(1):1-10. doi: 10.3109/14017437709167806.
3
Late results of valve replacement with the Björk-Shiley valve (1973 to 1982).使用Björk-Shiley瓣膜进行瓣膜置换的远期结果(1973年至1982年)。
J Thorac Cardiovasc Surg. 1993 Feb;105(2):302-12.
4
Fourteen years' experience with the Björk-Shiley tilting disc prosthesis.使用比约克-希利倾斜盘式人工心脏瓣膜的十四年经验。
J Thorac Cardiovasc Surg. 1986 Mar;91(3):350-61.
5
Mechanical failure of the Björk-Shiley valve. Incidence, clinical presentation, and management.比约克-希利瓣膜的机械故障。发生率、临床表现及处理
J Thorac Cardiovasc Surg. 1986 Nov;92(5):894-907.
6
Clinical and haemodynamic observations after combined aortic and mitral valve replacement with the Björk-Shiley tilting disc valve prosthesis. Early and late results in 25 patients.使用 Björk-Shiley 倾斜碟瓣人工瓣膜进行主动脉瓣和二尖瓣联合置换术后的临床及血流动力学观察。25例患者的早期和晚期结果
Scand J Thorac Cardiovasc Surg. 1979;13(1):25-31. doi: 10.3109/14017437909101782.
7
[Late complications following Björk-Shiley and St. Jude Medical heart valve replacement].[Björk-Shiley和圣犹达医疗心脏瓣膜置换术后的晚期并发症]
Z Kardiol. 1983 May;72(5):251-61.
8
A prospective evaluation of the Björk-Shiley, Hancock, and Carpentier-Edwards heart valve prostheses.对 Björk-Shiley、Hancock 和 Carpentier-Edwards 心脏瓣膜假体的前瞻性评估。
Circulation. 1986 Jun;73(6):1213-22. doi: 10.1161/01.cir.73.6.1213.
9
Outlet strut fracture of a 23-mm Björk-Shiley 70 degrees convexo-concave aortic valve.一枚23毫米的比约克-希利70度凸凹型主动脉瓣的流出道支柱骨折。
Cardiovasc Surg. 1993 Aug;1(4):445-6.
10
Five-year results after valve replacement with the Björk-Shiley 70 degrees convexo-concave prosthesis.使用Björk-Shiley 70度凸凹型人工瓣膜置换术后的五年结果。
Scand J Thorac Cardiovasc Surg. 1992;26(1):65-8. doi: 10.3109/14017439209099055.