Klugmann S, Fioretti P
G Ital Cardiol. 1981;11(11):1835-7.
A retrograde catheterization of the left ventricle was performed in 10 patients with aortic valve prosthesis. The pulmonary wedge pressure increased during the procedure (median value 16 mmHg; range 1-33 mmHg). The sistolic aortic pressure (median value 26 mmHg; range 5-60 mmHg) and the diastolic aortic pressure (median value 16 mmHg; range 1-33 mmHg) decreased in all. In 5 patients a left ventriculography was performed. The left ventricle catheterization in patients with aortic valve prosthesis in the experience of the authors may preclude accurate hemodynamic measurements; it may be utilized only for the evaluation of an associated mitral valve disease.
对10例人工主动脉瓣患者进行了左心室逆行导管插入术。术中肺楔压升高(中位数为16 mmHg;范围为1 - 33 mmHg)。所有患者的收缩期主动脉压(中位数为26 mmHg;范围为5 - 60 mmHg)和舒张期主动脉压(中位数为16 mmHg;范围为1 - 33 mmHg)均下降。5例患者进行了左心室造影。据作者经验,人工主动脉瓣患者的左心室导管插入术可能无法进行准确的血流动力学测量;它仅可用于评估相关的二尖瓣疾病。