The Terry surgical keratometer: a 12-month follow-up report.

作者信息

Colvard D M, Kratz R P, Mazzocco T R, Davidson B

出版信息

J Am Intraocul Implant Soc. 1981 Fall;7(4):348-50. doi: 10.1016/s0146-2776(81)80034-1.

Abstract

Postoperative astigmatism was studied in two groups of patients. All patients had undergone phacoemulsification with implantation of a posterior chamber intraocular lens. The incision closure techniques in both groups were identical, with one exception: One group was closed using the Terry keratometer intraoperatively, the second group was closed without the use of this instrument. Two observations are made from the twelve-month data. First, astigmatic error in the Terry group remained constant from the postoperative keratometer readings at six weeks to the twelve-month keratometer readings. Second, while there was a considerable difference in astigmatism at six weeks between the Terry group and the control group (less astigmatism in the Terry group), the differences were no longer apparent at twelve months. Sutures were removed as necessary to improve astigmatism in the control group. No sutures were cut in the Terry group during this twelve-month period.

摘要

对两组患者的术后散光情况进行了研究。所有患者均接受了白内障超声乳化吸除术并植入了后房型人工晶状体。两组的切口闭合技术相同,唯一的例外是:一组在术中使用特里角膜曲率计进行闭合,第二组在闭合时未使用该仪器。根据十二个月的数据得出了两点观察结果。第一,从术后六周角膜曲率计读数到十二个月角膜曲率计读数,特里组的散光误差保持恒定。第二,虽然特里组和对照组在六周时散光存在相当大的差异(特里组散光较小),但在十二个月时差异不再明显。对照组根据需要拆除缝线以改善散光。在这十二个月期间,特里组未剪断任何缝线。