Knoll E, Wisser H, Rautenstrauch H
J Clin Chem Clin Biochem. 1980 Jan;18(1):53-8.
A method is described for the determination of the enzyme N-acetyl-beta-D-glucosaminidase in gel-filtered urine. The individual reaction parameters were tested, and the reliability of the method was determined. The stability of the enzyme in urine was investigated at different temperatures over a 6 week period. The excretion of N-acetyl-beta-D-glucosaminidase, like the analysis of urinary proteins by disc electrophoresis, is a sensitive parameter for renal damage. The two methods were compared, using 50 random urine samples from patients with chronic polyarthritis; both methods were found to have equal diagnostic value.
描述了一种测定凝胶过滤尿中N-乙酰-β-D-氨基葡萄糖苷酶的方法。对各个反应参数进行了测试,并确定了该方法的可靠性。在6周的时间内,研究了该酶在不同温度下在尿中的稳定性。N-乙酰-β-D-氨基葡萄糖苷酶的排泄,如同通过圆盘电泳分析尿蛋白一样,是肾损伤的一个敏感参数。使用来自慢性多关节炎患者的50份随机尿样对这两种方法进行了比较;发现这两种方法具有同等的诊断价值。