Suppr超能文献

配备电化学检测器的高效液相色谱系统性能研究。

Investigations of the performance of a high-performance liquid chromatography system with an electrochemical detector.

作者信息

Wenk G, Greenland R

出版信息

J Chromatogr. 1980 Sep 12;183(3):261-7. doi: 10.1016/s0378-4347(00)81705-3.

Abstract

A procedure for the determination of norepinephrine and dopamine, based on high-performance liquid chromatography, is evaluated using an electrochemical detector system. The use of an inorganic mobile phase to provide resolution of low retention amines and extend column life is discussed. A high degree of correlation between estimations of endogenous catecholamine levels is reported using both electrochemical and fluorometric detector systems. Inter-assay reproducibility of the extraction method, and sensitivity and linearity of response of the electrochemical detector system are shown to be consistent across trials. The system described is determined to be accurate, sensitive, and reliable over time.

摘要

基于高效液相色谱法的去甲肾上腺素和多巴胺测定方法,采用电化学检测系统进行评估。讨论了使用无机流动相来分离低保留胺并延长柱寿命。报告了使用电化学检测系统和荧光检测系统对内源性儿茶酚胺水平估计之间的高度相关性。结果表明,提取方法的批间重现性、电化学检测系统的响应灵敏度和线性在各试验中保持一致。所描述的系统经确定长期准确、灵敏且可靠。