Abstract

In two dark reared, 40 day old kittens unilateral divergent squint was induced be resecting the insertion of the medial rectus muscle. Behavioural testing revealed that the kittens used only the normal eye for fixation. Contrast sensitivity functions of the two eyes had visual acuity were determined behaviourally in a jumping stand whereby the kittens had to discriminate sine-wave gratings or variable spatial frequency and contrast from a flux equated homogeneous field. At photopic luminance levels the deviated eye showed a significant deficit in both kittens. This impairment was apparent over the whole range of spatial frequencies (0.18-0.99 c/deg) except for the lowest spatial frequency in one kitten. The interocular difference of visual acuity disappeared at scotopic luminance levels. In subsequent electrophysiological experiments contrast sensitivity functions were determined from cortical evoked potentials that were elicited by phase reversing square wave grating. Comparison between behavioural and electrophysiological results revealed a very good correspondence between the two sets of data. It is concluded that exotropia without alternating fixation leads to functional amblyopia of the deviated eye.

摘要

在两只40日龄、饲养于黑暗环境中的小猫身上,通过切除内直肌附着点诱导出单侧散开性斜视。行为测试表明,小猫仅用正常眼睛进行注视。在一个跳跃架上通过行为学方法测定了两只眼睛的对比敏感度函数和视敏度,小猫必须从通量相等的均匀场中辨别正弦波光栅或可变空间频率及对比度。在明视觉亮度水平下,两只小猫的斜视眼均表现出明显的缺陷。除了一只小猫的最低空间频率外,这种损伤在整个空间频率范围(0.18 - 0.99周/度)内都很明显。在暗视觉亮度水平下,两眼视敏度的差异消失。在随后的电生理实验中,通过由相位反转方波光栅诱发的皮层诱发电位来测定对比敏感度函数。行为学和电生理结果的比较显示两组数据之间具有很好的一致性。结论是,无交替注视的外斜视会导致斜视眼功能性弱视。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验