Zanelli J M, Gaines Das R E
J Endocrinol. 1980 Aug;86(2):291-304. doi: 10.1677/joe.0.0860291.
The use of a Research Standard for human parathyroid hormone (PTH) in a collaborative study of 17 laboratories in ten countries is described. Results of the study showed that the Research Standard was not distinguishable by immunoreactive criteria from the other preparations and laboratory working standards of human PTH included in the study. It was, however, shown to be distinguishable from the International Reference Preparation for Parathyroid Hormone, Bovine, for Immunoassay by immunoreactive criteria and by heterogeneity of estimates in terms of bovine PTH. The Research Standard had appropriate biological activities in three different in-vitro bioassay systems and appeared to be stable under conditions of accelerated degradation. This material in ampoules coded 75/549 is now available internationally as N.I.B.S.C. Research Standard for human PTH for immunoassay.
本文描述了在一项由十个国家的17个实验室参与的合作研究中,人类甲状旁腺激素(PTH)研究标准品的使用情况。研究结果表明,根据免疫反应标准,该研究标准品与研究中包含的其他人类PTH制剂和实验室工作标准品无法区分。然而,根据免疫反应标准以及就牛PTH而言估计值的异质性,它被证明与甲状旁腺激素牛免疫测定国际参考制剂有区别。该研究标准品在三种不同的体外生物测定系统中具有适当的生物活性,并且在加速降解条件下似乎是稳定的。这种编码为75/549的安瓿装材料现已作为N.I.B.S.C.人类PTH免疫测定研究标准品在国际上提供。