Vela G R, Ralston J R
Can J Microbiol. 1978 Nov;24(11):1366-70. doi: 10.1139/m78-219.
Data are presented which show that the microbiological degradation of phenol in industrial wastewater is affected by temperature in an unexpected manner. The rate of degradation is unaffected by temperature changes in the range from 24 to 10 degrees C but falls off rapidly at temperatures below 10 degrees C. In the interval from 10 to 2 degrees C the rate of degradation is a function of temperature and is proportional to the rate of growth of the bacteria studied. By contrast, the increase in rate of phenol degradation is much greater than the increase in growth rate as the temperature increases from 10 to 24 degrees C. Field and laboratory studies show that increased efficiency of phenol degradation in wastewater is due to increase in temperature rather than to shifts in microbial populations.
所呈现的数据表明,工业废水中苯酚的微生物降解受到温度的影响,其方式出人意料。在24摄氏度至10摄氏度的温度范围内,降解速率不受温度变化的影响,但在温度低于10摄氏度时迅速下降。在10摄氏度至2摄氏度的区间内,降解速率是温度的函数,并且与所研究细菌的生长速率成正比。相比之下,当温度从10摄氏度升高到24摄氏度时,苯酚降解速率的增加远大于生长速率的增加。实地和实验室研究表明,废水中苯酚降解效率的提高是由于温度升高,而非微生物种群的变化。