Determination of benzidine and 3,3'-dichlorobenzidine in wastewater by liquid chromatography with uv and electrochemical detection.

作者信息

Armentrout D N, Cutié S S

出版信息

J Chromatogr Sci. 1980 Aug;18(8):370-4. doi: 10.1093/chromsci/18.8.370.

Abstract

The title compounds are on the EPA priority pollutant list. Therefore, a sensitive method for their measurement is required. The liquid chromatographic method employs a LiChrosorb RP-2 column, 45% acetonitrile (pH 5) mobile phase, UV detection at 280 nm, and electrochemical detection at +0.70 volts applied potential. The three-electrode electrochemical cell described contains a tubular carbon-black/polyethylene working electrode that permits detection of sub-part-per-billion levels in a 50 microliter injection permits detection of 2 ppb benzidine and dichlorobenzidine. Recoveries from fortified wastewater of benzidine at 1 to 6 ppb and dichlorobenzidine at 3 to 12 ppb levels were 83% and 87%, respectively.

摘要