Suppr超能文献

[心外膜起搏:临床评估及与经静脉起搏的比较(作者译)]

[Epicardial pacing: clinica evaluation and comparison with transvenous pacing (author's transl)].

作者信息

Cammilli L, Alajmo F, Berni I, Becciolini M, Marconi P

出版信息

G Ital Cardiol. 1980;10(1):32-6.

PMID:7461305
Abstract

Clinical experience with permanent epicardial pacing during a five year-period in our centre is presented. The report is based on 37 epicardial and 656 transvenous pacemaker implantations. Intraoperative and early postoperative mortality were absent in the epicardial pacing group. Late hospital mortality, morbidity and electro-mechanical complications were less than with transvenous pacing. Among the complications peculiar to the epicardial pacing technique, we observed 3 cases of breakage of a lead, at the level of its epicardial connection. We conclude that the use of epicardial leads represents a safe and effective technique of cardiac pacing.

摘要

本文介绍了我们中心五年期间永久性心外膜起搏的临床经验。该报告基于37例心外膜起搏和656例经静脉起搏器植入。心外膜起搏组术中及术后早期无死亡病例。晚期医院死亡率、发病率和机电并发症均低于经静脉起搏。在心外膜起搏技术特有的并发症中,我们观察到3例导线在心外膜连接部位发生断裂。我们得出结论,使用心外膜导线是一种安全有效的心脏起搏技术。