Suppr超能文献

[Effect of pharmacologic blockade of the autonomic system on time domain parameters of atrial and ventricular signal-averaged ECG in subjects with mitral valve prolapse].

作者信息

Banasiak W, Molenda W, Zapałowicz R, Petruk-Kowalczyk J, Telichowski C

机构信息

Kliniki Chorób Wewnetrznych Wojskowego Szpitala Klinicznego we Wrocławiu.

出版信息

Pol Arch Med Wewn. 1995 Jan;93(1):9-18.

PMID:7479225
Abstract

The aim of this study was evaluation of pharmacologic autonomic blockade on time-domain parameters of atrial (ASAECG) and ventricular signal-averaged ECG (SAECG) in patients with mitral valve prolapse syndrome (MVP) regarded 20 subjects with MVP (mean age 34.9 +/- 5.3) (group I) were studied as well as a control group consisting of 20 healthy subjects (mean age 37.5 +/- 4.6) (group II). Initially, two dimensional echocardiography with color doppler examination, ambulatory Holter monitoring, multistage treadmill exercise test, transoesophageal pacing (TEP), recording of ASAECG and SAECG were made. Subsequently, pharmacologic autonomic system blockade was done by using intravenously propranolol (0.1 mg/kg) and atropine (0.02 mg/kg). The following time-domain parameters of ASAECG were calculated: the root mean square voltage for the last 10, 20, 30 ms of filtered P-wave (RMS 10, 20, 30) and time duration of filtered P-wave (PWD). Moreover, the following parameters of SAECG were analyzed: the root mean square voltage of the signals in the last 40 and 50 ms of the filtered QRS (RMS 40, 50), the total time duration of QRS(t-QRS) and the duration of low amplitude signals < 40 microV (LPD). The autonomic blockade did not change significantly the obtained values of RMS 10, 20, 30 in subjects with MVP as follows: RMS 10 from 5.5 +/- 2.9 microV to 6.3 +/- 2.4 microV, RMS 20 from 8 +/- 3.7 microV to 8.5 +/- 2.4 microV and RMS30 from 10.2 +/- 4.9 microV to 10.3 +/- 3.3 microV. On the other hand, also the values of RMS 10 did not change statistically significant after blockade in control group (from 5.8 +/- 2.2 microV to 5.6 +/- 1.7 microV, p > 0.05), but the values of RMS20 i RMS30 increased significantly in this group, respectively from 7 +/- 3.1 microV to 8.3 +/- 3 microV (p < 0.02) and from 8.4 +/- 3.1 microV to 10.1 +/- 3.6 microV, (p < 0.05). The values of PWD have changed differently in the examined groups being under the influence of the autonomic blockade: in group I decreased from 119 +/- 12 ms to 114 +/- 28 ms (p > 0.05), whereas in group II increased from 110 +/- 13 ms to 116 +/- 9 ms (p < 0.02).(ABSTRACT TRUNCATED AT 400 WORDS)

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验