PURPOSE

To determine the needle size that would consistently enable the pathologist to correctly diagnose tissue core biopsy specimens.

MATERIALS AND METHODS

Fifty-seven surgically removed mass lesions of the breast were sampled with a short-throw automated biopsy gun and an 18-gauge needle first, followed by a 16- and a 14-gauge needle. Samples were evaluated independently by three pathologists, and findings were compared with the final diagnosis made at surgical excision biopsy.

RESULTS

The sensitivity for the diagnosis of all 26 malignant lesions was 100%, 92%, and 65% for biopsy samples obtained with 14-, 16-, and 18-gauge needles, respectively. Specificity for malignancy was 100% for all three needle sizes. All of the benign diseases were correctly diagnosed in samples obtained with all three size needles except for two samples that did not survive processing.

CONCLUSION

Biopsy samples obtained with a 14-gauge needle provide the most accurate diagnosis, which correlates with the diagnosis made with the surgical excision biopsy technique.

摘要

目的

确定能使病理学家始终正确诊断组织芯活检标本的针的规格。

材料与方法

首先用短行程自动活检枪和18号针采集57例手术切除的乳腺肿块病变样本,随后用16号和14号针采集。样本由三位病理学家独立评估,并将结果与手术切除活检的最终诊断进行比较。

结果

对于所有26例恶性病变,用14号、16号和18号针获取的活检样本的诊断敏感性分别为100%、92%和65%。三种针规格对恶性肿瘤的特异性均为100%。除两个样本在处理过程中未存活外,所有三种规格针获取的样本中所有良性疾病均被正确诊断。

结论

用14号针获取的活检样本提供了最准确的诊断,这与手术切除活检技术做出的诊断相关。