Besimo C, Kempf B
Department of Prosthodontics, School of Dentistry, University of Basle, Switzerland.
J Oral Rehabil. 1995 Sep;22(9):691-8. doi: 10.1111/j.1365-2842.1995.tb01068.x.
Primary splinting of fixtures with bar attachments has proved to be clinically effective for overdentures on osseointegrated implants in the edentulous mandible. However, in vitro investigations indicate that a more favourable force transfer to the individual fixtures can be attained by secondary splinting of four implants with conical double crowns. This observation could be confirmed in the present study by measurement of implant deflection in a model of the mandible by means of interferometric optical holography. Telescope crowns with conical interface brought about functionally more even movement characteristics of the implants compared to rigid or jointed bar attachments. Moreover, the conical double crowns always ensured a stable position of the denture in contrast to jointed attachments. These results underscore the need to test conical double crowns clinically as anchors for overdentures on osseointegrated implants.
对于无牙下颌骨上采用骨结合式种植体的覆盖义齿,用杆附着体对种植体进行初始夹板固定已被证明在临床上是有效的。然而,体外研究表明,通过对四个带有锥形双冠的种植体进行二次夹板固定,可以实现更有利的力传递至单个种植体。通过干涉光学全息术在下颌骨模型中测量种植体的位移,本研究证实了这一观察结果。与刚性或连接杆附着体相比,具有锥形界面的套筒冠使种植体在功能上具有更均匀的运动特性。此外,与连接附着体相比,锥形双冠始终能确保义齿的稳定位置。这些结果强调了临床上需要测试锥形双冠作为骨结合式种植体覆盖义齿的固位体。