[排尿流率加速在膀胱不稳定诊断中的应用价值]

[The usefulness of micturition flow acceleration in the diagnosis of bladder instability].

作者信息

Salinas Casado J, Prieto Chaparro L, Martín Garcia C, Rapariz González M, Virseda Chamorro M, Nacarino Corbacho L, Resel Estévez L

机构信息

Cátedra y Servicio de Urología, Hospital Universitario San Carlos, Universidad Complutense, Madrid, España.

出版信息

Arch Esp Urol. 1993 Dec;46(10):891-5.

PMID:7511367
Abstract

The acceleration of flow rate (ml/sg2) is a urodynamic parameter derived from free flow uroflowmetry. The present study was conducted to determine the role of this new parameter as an alternative to the standard filling cystometry in the diagnosis of detrusor instability in nocturnal enuresis, prostatism and female urinary incontinence. We have observed that it is not a useful parameter due to the large overlapping of the patients with unstable and normal bladder. For this reason it is not possible to establish significant predictive values.

摘要

流速加速度(毫升/秒²)是一种从自由流尿流率测定中得出的尿动力学参数。本研究旨在确定这一新参数作为标准充盈性膀胱测压的替代方法在诊断夜间遗尿症、前列腺增生症和女性尿失禁的逼尿肌不稳定中的作用。我们观察到,由于膀胱不稳定和正常的患者之间存在大量重叠,它不是一个有用的参数。因此,无法确定显著的预测值。